nimbus, the safest and most effective Early Streamer Emission (ESE) system for~
lightning protection.
The nimbus is manufactured according to standard NFC 17-102 & UNE 21186-96
The nimbus system has been specially designed to reduce the actual time
associated with the upward streamer emission created when lightning strike occurs. In
other words, compared to the traditional method used by a Franklin rod, the built-in
electronic device allows a much bigger radius of Protection I coverage. Therefore,
nimbus offers the following Major Benefits:
| High Level of Safety |
Excellent Protection |
| Absolute Reliability |
Savings on Installation |
|
 |
|
 Nimbus is self powered and does not require an external Power supply for Operation. |
| |
When atmospheric conditions
lead to formation of thunderstorm
clouds, an electrical charge gradient
of thousands of V/m occurs between
the could and the ground. |
When such a voltage gradient appears
on the tip of the Nimbus Lightning rod,
the Nimbus ESE system captures and
stores such energy induced by the
atmosphere. The polarity of the stored
charge will always be opposite to that
of the clouds since it is the result of
charge induction from cloud to earth.. |
When the NIMBUS ESE system detects
that the voltage gradient is above the
threshold value indicating an imminent
lightning strike, the stored energy is released in the form of high frequency
pulses leading to an upward tracer.
Since the polarity of the stored charges
are always opposite to that of the cloud,
the upward tracer from the NIMBUS
will be an opposite charge to that of
the downward streamer from the cloud. |
When the upward & downward
streamers meet, they provide a [ow I
zero impedance path for the energy of
the cloud to discharge to the ground
through the NIMBUS, its ground
conductor and earthing system. |
|
|
| |
DISCHARGE COUNTER
|
|
| |
When the lightning rod conducts the lightning discharge to the earth, the counter detects
this pulse and records. The equipment does not need an electrical power supply or
maintenance and the operation life cycle is practically unlimited.  |
|
| |
Selection of the nimbus model:
Protection Level:
According to the standards NF C 17-102 and UNE
21186 - 96 three protection levels are considered:
Level I: Level with maximum security.
Level II: Level with high security.
Level III: Level with standard security.
Remark: It is recommended for security reasons to
consider level I.
The nimbus is compatible with conventional cables / strips as down conductor and standard earth termination system as the nimbus is termination system as the nimbus isearth resistance of 10 Ohms.
NP : Protection level
Rp : Protection radius
h : Height of the top of the nimbus
on the surface to be protected
The tip of the lightning rod has to be
atleast 2 mtrs above any other point of
the structure.
|
|
| |
nimbus can be tested at Site periodically
to ascertain the functional integrity
of the system.
|
|
| |
|
|
| |
|
 |
 |
|
|
|
|