 salient features
 
  • Portable anytime, anywhere UPS for home
  • Envious Italian Design – finesse meets functionality
  • Cradle Rocker System for battery management
  • Fast charge solution for frequent power-cuts
  • Pure sine wave output with i-DSP technology protects gadgets

 

 
 load chart and battery requirment
 

Specified Parameters

UPS Mode

Normal Mode

Voltage

- Mains AC Lower Voltage Cut / Recovery

180 ± 5V / 190±5V 100 ± 5 V / 110 ± 5 V

- Mains AC Higher Voltage Cut / Recovery

265 ± 5 V / 255±5V  280 ± 5 V / 270 ± 5 V

Battery Charging Voltage Range

 

180V AC to 265V AC 110V AC to 280V AC

Output Voltage Without Load

 

230 ±  3V 230 ±  3V

Change Over time

 

<10 milli-sec < 30 milli-sec

Battery Charging

 

400VA 650VA 800VA 1400VA

No. of Batteries(12v)

Single Single Single Double

‘Quick Charging’ Current

5 ± 1 amps 11 ± 1 amps 12 ± 1 amps 12 ± 1 amps

‘Normal Charging’ Current

( No option) 8 ± 1 amps 9 ± 1 amps 9 ± 1 amps

‘Boost Charging’ Voltage

14.4 ± 0.2 V 14.4 ± 0.2 V  14.4 ± 0.2 V  28.8 ± 0.2 V 

‘Float Charging’ Voltage

13.8 ± 0.2 V  13.8 ± 0.2 V  13.8 ± 0.2 V  27.6 ± 0.2 V 

Battery Lower Voltage Cut-off

10.2 ± 0.2 V 10.2 ± 0.2 V 10.2 ± 0.2 V 20.4 ± 0.2 V

Recommended Battery Capacity

80 to 100 AH 80 to 160 AH 80 to 160 AH 80 to 160 AH

Charging Methodology

 

Constant current followed by constant voltage

Output Wave Form

 

Pure sine wave

Output Frequency

 

Same as input when AC mains available & 50.0 ± 0.5 Hz on UPS

Efficiency

Efficiency

 AC to DC : >95% 
 DC to AC : >80%

Operating Environment

Operating Temperature

-25 degree C to +55 degree C

LED Indications

 

Mains, Charging, UPS ON, Low battery & Over load

Audible Alarm

 

Low battery, Over load & Short circuit

Protections

Over Load

100 + 5% load on UPS(auto reset if reduce the load with in 3 re-tries)

Over Charge

Protects the battery from overcharging by controlling the charging current & voltage.

Short Circuit

UPS Shutdown in UPS mode and AC fuse blown in mains mode(Manual reset)

Thermal Shutdown

Above 93 degree C inside the unit

Battery Reverse Polarity

Protects the UPS and DC fuses blown on PMB

Battery Deep Discharge

Protects the battery from deep discharge having cut-off at 10.2 ± 0.2 V
Note:Replace 4 Fans for one Cooler and 2 CFL's for Tube Light.
 